<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Shiraz University</PublisherName>
				<JournalTitle>Iranian Journal of Veterinary Research</JournalTitle>
				<Issn>1728-1997</Issn>
				<Volume>26</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>12</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of normal ophthalmic parameters and fundoscopic images along with the comparison of two methods of A-mode ocular ultrasonographic biometry and intraocular pressure in healthy working canines</ArticleTitle>
<VernacularTitle>ارزیابی پارامترهای طبیعی چشم و تصاویر فوندوسکوپی به همراه مقایسه دو روش بیومتری اولتراسونوگرافی چشمی حالت A و فشار داخل چشم در سگ‌های کاری سالم</VernacularTitle>
			<FirstPage>379</FirstPage>
			<LastPage>387</LastPage>
			<ELocationID EIdType="pii">8755</ELocationID>
			
<ELocationID EIdType="doi">10.22099/ijvr.2025.49696.7451</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>A.</FirstName>
					<LastName>Nema</LastName>
<Affiliation>Ph.D. Student, Department of Veterinary Surgery and Radiology, College of Veterinary Science and Animal Husbandry, DUVASU, Mathura-281001, Uttar Pradesh, India</Affiliation>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Purohit</LastName>
<Affiliation>Department of Veterinary Surgery and Radiology, College of Veterinary Science and Animal Husbandry, DUVASU, Mathura-281001, Uttar Pradesh, India</Affiliation>

</Author>
<Author>
					<FirstName>R. P.</FirstName>
					<LastName>Pandey</LastName>
<Affiliation>Department of Veterinary Surgery and Radiology, College of Veterinary Science and Animal Husbandry, DUVASU, Mathura-281001, Uttar Pradesh, India</Affiliation>

</Author>
<Author>
					<FirstName>V.</FirstName>
					<LastName>Nema</LastName>
<Affiliation>Dog Training and Breeding Centre, Sashastra Seema Bal, Alwar-301409, Rajasthan, India</Affiliation>

</Author>
<Author>
					<FirstName>V. K.</FirstName>
					<LastName>Vijay</LastName>
<Affiliation>Department of Animal Genetics and Breeding, College of Veterinary and Animal Science, RAJUVAS, Bikaner-334001, Rajasthan, India</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>06</Month>
					<Day>15</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background:&lt;/strong&gt; Working canines play a very important role in assisting forces by uncovering evidences that might be missed by the human eye. To date, there is no published data on normal ophthalmological parameters for working dogs. &lt;strong&gt;Aims:&lt;/strong&gt; This study aims to document normal reference ranges of ophthalmological parameters and blood pressure (BP). Additionally, the study compared the two methods of intraocular pressure (IOP) measurement and A-scan biometry, and assess correlations between IOP to both systolic blood pressure and axial globe length. &lt;strong&gt;Methods:&lt;/strong&gt; The study was conducted on 18 dogs of Sashastra Seema Bal (SSB), Alwar (Rajasthan), aged 3.5-6 years, which were divided into three breed-specific groups, i.e., group 1 (Belgian Shepherd), group 2 (German Shepherd) and group 3 (Labrador Retriever) with six animals each. Schirmer’s tear test strips were used to perform the Schirmer’s tear test (STT). To measure intraocular pressure (IOP), rebound tonometry (Tonovet) and indentation tonometry (Schiotz) were used. A-scan ultrasonography was performed by contact and immersion method. Fundoscopic images were recorded using Fundus-On-Phone equipment. &lt;strong&gt;Results:&lt;/strong&gt; STT values revealed non-significant differences among groups, sexes, and eyes. The cumulative mean reflected a higher reading by the rebound tonometer than the indentation tonometer. In all the three groups, a significantly longer anterior chamber depth and axial globe length were observed in the immersion method. Axial globe length was longest in the Labrador breed, followed by German Shepherd and Belgian Shepherd. Systolic and diastolic pressure were significantly different among groups. &lt;strong&gt;Conclusion:&lt;/strong&gt; These breed-specific various ophthalmic parameters of working canines will be useful in the clinical diagnosis of various ophthalmic affections.</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;پیشینه:&lt;/strong&gt; سگ‌های کاری با کشف شواهدی که ممکن است از چشم انسان پنهان بماند، نقش بسیار مهمی در کمک به نیروها دارند. تا به امروز، هیچ داده منتشر شده‌ای در مورد پارامترهای طبیعی چشم پزشکی برای سگ‌های کاری وجود ندارد. &lt;strong&gt;هدف:&lt;/strong&gt; هدف از این مطالعه مستندسازی محدوده‌های مرجع طبیعی پارامترهای چشم پزشکی و فشار خون (BP) است. علاوه بر این، این مطالعه دو روش اندازه‌گیری فشار داخل چشم (IOP) و بیومتری A-scan را مقایسه می‌کند و همبستگی بین IOP را با فشار خون سیستولیک و طول محوری کره چشم ارزیابی می‌کند. &lt;strong&gt;روش کار&lt;/strong&gt;: این مطالعه بر روی ۱۸ سگ از نژاد ساشاسترا سیما بال (SSB)، آلوار (راجستان)، با سن 5/3 تا ۶ سال انجام شد که به سه گروه نژادی، یعنی گروه ۱ (بلژیکی شپرد)، گروه ۲ (ژرمن شپرد) و گروه ۳ (لابرادور رتریور) با شش حیوان در هر گروه، تقسیم شدند. از نوارهای تست اشک شیرمر برای انجام تست اشک شیرمر (STT) استفاده شد. برای اندازه‌گیری فشار داخل چشم (IOP)، از تونومتری برگشتی (Tonovet) و تونومتری فرورفتگی (Schiotz) استفاده شد. سونوگرافی A-scan با روش تماسی و غوطه‌وری انجام شد. تصاویر فوندوسکوپی با استفاده از تجهیزات Fundus-On-Phone ثبت شدند. &lt;strong&gt;نتایج:&lt;/strong&gt; مقادیر STT تفاوت معنی‌داری را بین گروه‌ها، جنس‌ها و چشم‌ها نشان نداد. میانگین تجمعی نشان دهنده قرائت بالاتر توسط تونومتر برگشتی نسبت به تونومتر فرورفتگی بود. در هر سه گروه، عمق محفظه قدامی و طول محوری کره چشم در روش غوطه‌وری به طور قابل توجهی طولانی‌تر مشاهده شد. طول محوری کره چشم در نژاد لابرادور طولانی‌ترین بود و پس از آن ژرمن شپرد و بلژیکی شپرد قرار داشتند. فشار سیستولیک و دیاستولیک بین گروه‌ها تفاوت معنی‌داری داشت. &lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; این پارامترهای چشمی مختلف مختص نژاد سگ‌های کاری در تشخیص بالینی بیماری‌های مختلف چشمی مفید خواهند بود.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">A-mode ultrasonography</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fundoscopy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Intraocular pressure</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Tonometry</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ijvr.shirazu.ac.ir/article_8755_cc7b1c226fed0a0811e24dedd40d945e.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
