<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Shiraz University</PublisherName>
				<JournalTitle>Iranian Journal of Veterinary Research</JournalTitle>
				<Issn>1728-1997</Issn>
				<Volume>25</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>06</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Comparison of human smartwatch and transmittance pulse oximetry for evaluating peripheral oxygen saturation in anesthetized dogs</ArticleTitle>
<VernacularTitle>مقایسه ساعت هوشمند انسانی و پالس اکسیمتری عبوری برای ارزیابی اشباع بودن اکسیژن محیطی در سگ‌های بیهوش</VernacularTitle>
			<FirstPage>166</FirstPage>
			<LastPage>169</LastPage>
			<ELocationID EIdType="pii">7773</ELocationID>
			
<ELocationID EIdType="doi">10.22099/ijvr.2024.47628.6884</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>M. G.</FirstName>
					<LastName>Senocak</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Atatürk University, Erzurum, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Okur</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Atatürk University, Erzurum, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>U.</FirstName>
					<LastName>Ersoz</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Atatürk University, Erzurum, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>L. E.</FirstName>
					<LastName>Yanmaz</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>Y.</FirstName>
					<LastName>Kocaman</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Yozgat Bozok University, Yozgat, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>F.</FirstName>
					<LastName>Turgut</LastName>
<Affiliation>Department of Surgery, Faculty of Ceyhan Veterinary Medicine, Cukurova University, Adana, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>A. G.</FirstName>
					<LastName>Bedir</LastName>
<Affiliation>Department of Surgery, Faculty of Veterinary Medicine, Atatürk University, Erzurum, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>O. T.</FirstName>
					<LastName>Orhun</LastName>
<Affiliation>Department of Surgery, Faculty of Eregli Veterinary Medicine, Necmettin Erbakan University, Konya, Turkey</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>06</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background:&lt;/strong&gt; Pulse oximetry is a valuable tool for monitoring animals during anesthesia and assessing the adequacy of administered oxygen therapy. &lt;strong&gt;Aims:&lt;/strong&gt; To compare the pulse oximeter readings obtained by the Garmin Fenix 5X plus (GF5Xp) smartwatch and transmittance pulse oximetry (TPO) in anesthetized dogs. &lt;strong&gt;Methods:&lt;/strong&gt; Twelve clinical canine patients requiring anesthesia for castration were prospectively enrolled in this study. The animals were premedicated with intramuscular dexmedetomidine at a dose of 5 µg/kg. Anesthesia was induced through intravenous administration of propofol and maintained using sevoflurane. The arterial hemoglobin oxygen saturation (SpO&lt;sub&gt;2&lt;/sub&gt;) readings obtained from the tongue using TPO (238 readings) were compared with measurements taken over the lateral side of the tibia using a GF5Xp smart wearable device (238 readings). This comparison was performed using a Bland-Altman plot, where the differences (%) between the methods were plotted against their mean SpO&lt;sub&gt;2&lt;/sub&gt; (Gold standard - Device), and the limits of agreement were represented as the mean ± 1.96 times the standard deviation. &lt;strong&gt;Results:&lt;/strong&gt; The SpO&lt;sub&gt;2&lt;/sub&gt; levels in dogs were overestimated by the GF5Xp relative to the readings obtained by the TPO, with the bias of -0.3% (95% CI: -3.1%-2.5%). &lt;strong&gt;Conclusion:&lt;/strong&gt; GF5Xp may be interchangeable with TPO in dogs. Further studies are required to validate the accuracy of the GF5Xp in non-anesthetized dogs or dogs outside the physiological range.</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;پیشینه:&lt;/strong&gt; پالس اکسیمتری ابزاری ارزشمند برای پایش حیوانات در حین بیهوشی و ارزیابی کفایت اکسیژن درمانی است. &lt;strong&gt;هدف:&lt;/strong&gt; مقایسه قرائت‌های پالس اکسیمتر به دست آمده توسط ساعت هوشمند Garmin Fenix 5X plus (GF5Xp) و پالس اکسیمتری عبوری (TPO) در سگ‌های بیهوش شده. &lt;strong&gt;روش کار:&lt;/strong&gt; 12 سگ که برای اخته شدن نیاز به بیهوشی داشتند به صورت آینده نگر وارد مطالعه شدند. حیوانات با دکسمدتومیدین عضلانی با دوز 5 میکروگرم بر کیلوگرم وارد فاز پیش بیهوشی شدند. بیهوشی از طریق تجویز داخل وریدی پروپوفول القا شد و با استفاده از سووفلوران حفظ شد. قرائت‌های اشباع اکسیژن هموگلوبین شریانی (SpO&lt;sub&gt;2&lt;/sub&gt;) به دست آمده از زبان با استفاده از TPO (238 قرائت) با اندازه‌گیری‌های انجام شده در سمت جانبی درشت نی با استفاده از دستگاه پوشیدنی هوشمند GF5Xp (238 قرائت) مقایسه شد. این مقایسه با استفاده از نمودار بلند-آلتمن انجام شد، که در آن تفاوت (%) بین روش‌ها در برابر میانگین SpO&lt;sub&gt;2&lt;/sub&gt; (استاندارد طلایی - دستگاه) ترسیم شد و حدود توافق به صورت میانگین 96/1± برابر انحراف استاندارد در نظر گرفته شد. &lt;strong&gt;نتایج:&lt;/strong&gt; سطوح SpO&lt;sub&gt;2&lt;/sub&gt; در سگ‌ها توسط GF5Xp نسبت به قرائت‌های به دست آمده توسط TPO، که در آن سوگیری 3/0%- (بازه اطمینان 95%: 1/3%- تا 5/2%) بود، بیش از حد برآورد شد. &lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; GF5Xp ممکن است با روش TPO در سگ‌ها قابل جایگزین شدن باشد. مطالعات آتی برای تایید صحت GF5Xp در سگ‌های بیهوش یا سگ‌های خارج از محدوده فیزیولوژیکی مورد نیاز است.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Canine</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hemoglobin</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Oxygen</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Propofol</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Pulse oximetry</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ijvr.shirazu.ac.ir/article_7773_13451443ef92cf338fa8d8bea6997ea3.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
